Review





Similar Products

94
BioTools Inc chiralraman 2xtm spectrometer
Chiralraman 2xtm Spectrometer, supplied by BioTools Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/chiralraman 2xtm spectrometer/product/BioTools Inc
Average 94 stars, based on 1 article reviews
chiralraman 2xtm spectrometer - by Bioz Stars, 2026-03
94/100 stars
  Buy from Supplier

88
Thermo Fisher gene exp cr2 mm00801681 m1
Gene Exp Cr2 Mm00801681 M1, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 88/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/gene exp cr2 mm00801681 m1/product/Thermo Fisher
Average 88 stars, based on 1 article reviews
gene exp cr2 mm00801681 m1 - by Bioz Stars, 2026-03
88/100 stars
  Buy from Supplier

94
Sino Biological normal goat control igg
Normal Goat Control Igg, supplied by Sino Biological, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/normal goat control igg/product/Sino Biological
Average 94 stars, based on 1 article reviews
normal goat control igg - by Bioz Stars, 2026-03
94/100 stars
  Buy from Supplier

94
BioTools Inc biotools chiralraman spectrometer
Biotools Chiralraman Spectrometer, supplied by BioTools Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/biotools chiralraman spectrometer/product/BioTools Inc
Average 94 stars, based on 1 article reviews
biotools chiralraman spectrometer - by Bioz Stars, 2026-03
94/100 stars
  Buy from Supplier

94
BioTools Inc chiralraman 2x spectrometer
Chiralraman 2x Spectrometer, supplied by BioTools Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/chiralraman 2x spectrometer/product/BioTools Inc
Average 94 stars, based on 1 article reviews
chiralraman 2x spectrometer - by Bioz Stars, 2026-03
94/100 stars
  Buy from Supplier

94
Sino Biological recombinant human cd21
SEM (A–C) and AFM (D–F) images of (A, D) <t>CD21@AuNP,</t> (B,E) BSA@CD21@AuNP, and (C, F) gp350@BSA@CD21@AuNP.
Recombinant Human Cd21, supplied by Sino Biological, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/recombinant human cd21/product/Sino Biological
Average 94 stars, based on 1 article reviews
recombinant human cd21 - by Bioz Stars, 2026-03
94/100 stars
  Buy from Supplier

Image Search Results


SEM (A–C) and AFM (D–F) images of (A, D) CD21@AuNP, (B,E) BSA@CD21@AuNP, and (C, F) gp350@BSA@CD21@AuNP.

Journal: Analytical Chemistry

Article Title: Early Detection of Multiple Sclerosis Using Spectroscopic Epstein–Barr Virus Biosensors Based on Infection Mechanism Mimicry

doi: 10.1021/acs.analchem.5c03964

Figure Lengend Snippet: SEM (A–C) and AFM (D–F) images of (A, D) CD21@AuNP, (B,E) BSA@CD21@AuNP, and (C, F) gp350@BSA@CD21@AuNP.

Article Snippet: Recombinant human CD21 and recombinant EBV gp350 proteins were purchased from Sino Biological Inc. All reagents and chemicals employed in this study were analytical grade and used without further purification.

Techniques:

(A) FTIR and (B) UV spectra for the characterization of the developed colorimetric EBV biosensor. Step-by-step FTIR and UV spectra of the biosensor during gp350 detection: (a) 2.1 mL of AuNPs; (b) 2.1 mL of AuNPs + 400 μL of CD21 at 20 ng·mL –1 ; (c) 2.1 mL of AuNPs + 400 μL of CD21 at 20 ng·mL –1 + 100 μL of 1% BSA; and (d) 2.1 mL of AuNPs + 400 μL of CD21 at 20 ng·mL –1 + 100 μL of 1% BSA + 50 ng·mL –1 of gp350.

Journal: Analytical Chemistry

Article Title: Early Detection of Multiple Sclerosis Using Spectroscopic Epstein–Barr Virus Biosensors Based on Infection Mechanism Mimicry

doi: 10.1021/acs.analchem.5c03964

Figure Lengend Snippet: (A) FTIR and (B) UV spectra for the characterization of the developed colorimetric EBV biosensor. Step-by-step FTIR and UV spectra of the biosensor during gp350 detection: (a) 2.1 mL of AuNPs; (b) 2.1 mL of AuNPs + 400 μL of CD21 at 20 ng·mL –1 ; (c) 2.1 mL of AuNPs + 400 μL of CD21 at 20 ng·mL –1 + 100 μL of 1% BSA; and (d) 2.1 mL of AuNPs + 400 μL of CD21 at 20 ng·mL –1 + 100 μL of 1% BSA + 50 ng·mL –1 of gp350.

Article Snippet: Recombinant human CD21 and recombinant EBV gp350 proteins were purchased from Sino Biological Inc. All reagents and chemicals employed in this study were analytical grade and used without further purification.

Techniques:

(A) UV spectra and (B) bar chart that belong to the optimization of the CD21–gp350 interaction incubation temperature. (a) BSA@CD21@AuNP, (b) BSA@CD21@AuNP + 50 ng·mL –1 gp350 for 4 °C, (c) 25 °C, (d) 37 °C, and (e) 45 °C incubation temperature.

Journal: Analytical Chemistry

Article Title: Early Detection of Multiple Sclerosis Using Spectroscopic Epstein–Barr Virus Biosensors Based on Infection Mechanism Mimicry

doi: 10.1021/acs.analchem.5c03964

Figure Lengend Snippet: (A) UV spectra and (B) bar chart that belong to the optimization of the CD21–gp350 interaction incubation temperature. (a) BSA@CD21@AuNP, (b) BSA@CD21@AuNP + 50 ng·mL –1 gp350 for 4 °C, (c) 25 °C, (d) 37 °C, and (e) 45 °C incubation temperature.

Article Snippet: Recombinant human CD21 and recombinant EBV gp350 proteins were purchased from Sino Biological Inc. All reagents and chemicals employed in this study were analytical grade and used without further purification.

Techniques: Incubation

(A) UV spectra and (B) Excel plot that belong to the optimization of the CD21–gp350 interaction incubation time. (a) BSA@CD21@AuNP, (b) BSA@CD21@AuNP + 50 ng·mL –1 gp350 for 15 min, (c) 30 min, (d) 60 min, and (e) 90 min incubation time.

Journal: Analytical Chemistry

Article Title: Early Detection of Multiple Sclerosis Using Spectroscopic Epstein–Barr Virus Biosensors Based on Infection Mechanism Mimicry

doi: 10.1021/acs.analchem.5c03964

Figure Lengend Snippet: (A) UV spectra and (B) Excel plot that belong to the optimization of the CD21–gp350 interaction incubation time. (a) BSA@CD21@AuNP, (b) BSA@CD21@AuNP + 50 ng·mL –1 gp350 for 15 min, (c) 30 min, (d) 60 min, and (e) 90 min incubation time.

Article Snippet: Recombinant human CD21 and recombinant EBV gp350 proteins were purchased from Sino Biological Inc. All reagents and chemicals employed in this study were analytical grade and used without further purification.

Techniques: Incubation

Analytical characteristics of the developed colorimetric EBV biosensors. (A) UV spectra of (a) BSA@CD21@AuNP, (b) 10 ng·mL –1 , (c) 25 ng·mL –1 , (d) 50 ng·mL –1 , (e) 80 ng·mL –1 , and (f) 100 ng·mL –1 gp350 additions. (B) Calibration plot of increasing concentrations of gp350 from 10 ng·mL –1 to 100 ng·mL –1 .

Journal: Analytical Chemistry

Article Title: Early Detection of Multiple Sclerosis Using Spectroscopic Epstein–Barr Virus Biosensors Based on Infection Mechanism Mimicry

doi: 10.1021/acs.analchem.5c03964

Figure Lengend Snippet: Analytical characteristics of the developed colorimetric EBV biosensors. (A) UV spectra of (a) BSA@CD21@AuNP, (b) 10 ng·mL –1 , (c) 25 ng·mL –1 , (d) 50 ng·mL –1 , (e) 80 ng·mL –1 , and (f) 100 ng·mL –1 gp350 additions. (B) Calibration plot of increasing concentrations of gp350 from 10 ng·mL –1 to 100 ng·mL –1 .

Article Snippet: Recombinant human CD21 and recombinant EBV gp350 proteins were purchased from Sino Biological Inc. All reagents and chemicals employed in this study were analytical grade and used without further purification.

Techniques:

UV spectra demonstrating the absorbance difference of a 1:1 ratio of (a) BSA@CD21@AuNP, (b) gp350 @BSA@CD21@AuNP, and (c) A27L + KMP11 + gp350 @BSA@CD21@AuNP.

Journal: Analytical Chemistry

Article Title: Early Detection of Multiple Sclerosis Using Spectroscopic Epstein–Barr Virus Biosensors Based on Infection Mechanism Mimicry

doi: 10.1021/acs.analchem.5c03964

Figure Lengend Snippet: UV spectra demonstrating the absorbance difference of a 1:1 ratio of (a) BSA@CD21@AuNP, (b) gp350 @BSA@CD21@AuNP, and (c) A27L + KMP11 + gp350 @BSA@CD21@AuNP.

Article Snippet: Recombinant human CD21 and recombinant EBV gp350 proteins were purchased from Sino Biological Inc. All reagents and chemicals employed in this study were analytical grade and used without further purification.

Techniques: